Micro Gear Motor Radial and Axial Load Limits: OEM Sizing & Bearing Guide
2026/10/29

Micro Gear Motor Radial and Axial Load Limits: OEM Sizing & Bearing Guide

Check micro gear motor radial and axial load limits with worked calculations, bearing trade-offs, and an OEM RFQ checklist. Request a review for your assembly.

Micro gear motor radial and axial load limits are specific to the gearbox assembly, load position, output speed, duty cycle, and required life. A torque rating alone cannot establish a permissible shaft load. For an OEM sizing decision, first calculate the forces at the output shaft, then compare them with the supplier's limits at the same load position and operating conditions.

Published and technically reviewed: October 29, 2026. Scope: Global OEM engineering and procurement; SI units; preliminary sizing of miniature geared drives. Worked examples below are hypothetical calculations, not hardware test results or certified product ratings. For medical or other regulated applications, they do not establish device approval.

If your datasheet omits the radial or push/pull thrust limit, request a shaft-load review before selecting a sample. Include the shaft drawing and load cycle. The micro gear motor product portfolio can help identify candidate drive families; frame size is only a starting point.

1. Defining Mechanical Shaft Loads: Radial, Axial, and Moment

Radial load acts perpendicular to the output shaft; axial thrust acts along it. An overhung radial force also creates a bending moment. Portescap's load-selection guide explains why bearing selection, force position, speed, and life must be considered together.

Radial and axial loads on a micro gear motor output shaftSchematic: radial load acts across the shaft and axial thrust along it. Distance x is measured from the front bearing center to the load center; b is the bearing span. Bearing reaction arrows oppose each other.Micro Gearhead HousingFront BearingRear BearingPulley / GearRadial Load (Fr)Overhung Side ForceAxial Thrust (Fa)Distance x (Overhung Lever Arm)Bearing Span (b)R1R2

Figure 1. Simplified two-support shaft model, not a product cross-section. The mounting-face datum may differ from the front bearing center.

Radial Load and Bearing Reactions

For the idealized shaft in Figure 1, let x be the distance from the front bearing center to the external load center, and b the center-to-center bearing span. For a single downward radial force Fr, static equilibrium gives:

Bending moment at front bearing section: Mb = Fr × x
Front bearing reaction magnitude:        R1 = Fr × (b + x) / b
Rear bearing reaction magnitude:         R2 = Fr × x / b

R1 acts upward; R2 acts downward in this arrangement. With Fr in N and x in mm, Mb is in N·mm. These reactions exclude internal gear forces, preload, housing flexibility, and other external loads; they are a screening model, not a bearing approval calculation.

Example: For assumed b = 6 mm, x = 9 mm, and Fr = 20 N, R1 = 50 N and R2 = 30 N. A 20 N external force can therefore create a larger front-bearing reaction. Do not compare that internal reaction directly with a catalog's permissible external shaft-load rating.

Axial Push and Pull

Record push thrust and pull thrust separately, including reversals. Lead screws and helical or worm meshes can introduce thrust; shaft retention and bearing preload determine how it is carried. Confirm the force path in the actual gearbox. Two ball bearings do not automatically provide the same capacity in both directions.

Running, Stationary, and Assembly Loads

Ask for running radial/axial limits, stationary-load limits, and press-fit or impact restrictions separately. A published bearing dynamic rating is not the same as a complete gearmotor's permissible shaft force. There is no general 2× or 3× static allowance: shaft strength, bearing contact, retention, and housing constraints can govern independently.

2. Calculating Loads Across Transmission Interfaces

Start with tangential force at the pitch circle:

Ft = 2000 × T / d
T = output torque in N·m; d = pitch diameter in mm; Ft = force in N

This is a torque-to-force conversion, not a universal radial-load formula. Oriental Motor's sizing tutorial distinguishes drive-method coefficients, service factors, and belt tension. Use coefficients only within the transmission supplier's stated method; do not apply a guessed multiplier to every mechanism.

Transmission interfaceInitial force modelAdditional input requiredOEM sizing action
Flexible couplingTorque does not establish radial forceCoupling stiffness, offset, angular error, thermal growthObtain misalignment reactions; check both shafts and bearings
Spur pinionFor a simple external spur mesh: separating force = Ft × tan(pressure angle); transverse resultant = Ft / cos(pressure angle)Pressure angle, mesh direction, peak torqueResolve tangential and separating forces at the pinion center
Helical pinionA simple mesh also produces thrust: Fa = Ft × tan(helix angle)Helix angle, transverse pressure angle, mesh hand and rotationCalculate transverse resultant and both thrust directions
Chain sprocketTorque relates to the difference in strand tensionsTight/slack tensions, strand angles, inertia and startsSum the strand force vectors; include specified dynamic allowances
Timing beltTorque relates to tight-side minus slack-side tensionInstalled tension, working tensions, belt span directionsSum belt forces; do not omit installation tension
Flat belt or O-ringTransmitted torque does not determine total tensionFriction, wrap angle, stretch and tension variationObtain the belt supplier's tension calculation or measure the load
Peristaltic pump headTube compression force cannot be inferred from torque aloneTubing, occlusion, pressure, roller geometry, load versus angleMeasure/model radial load over a full cycle; consider a separately supported rotor

These are simplified force models. Include component weight and process forces where relevant, and evaluate simultaneous force vectors rather than adding every scalar maximum as if they act in the same direction.

Worked Example: A Small Timing-Belt Drive

Assume output torque T = 0.25 N·m, pitch diameter d = 22 mm, and two approximately parallel belt spans pulling toward the driven pulley. Also assume the belt calculation has supplied a working slack-side tension of 10 N; this is an illustrative input, not a recommended installation tension.

Tight-side minus slack-side tension = 2000 × 0.25 / 22 = 22.73 N
Tight-side tension                  = 22.73 + 10 = 32.73 N
Approximate radial shaft force      = 32.73 + 10 = 42.73 N

The sum applies to this assumed span geometry. Resolve vectors for other arrangements. Compare 42.73 N with the actual assembly's permissible external load at the actual load position, speed, and life. If that rating is missing, the result remains unapproved; neither a 0.3 N·m torque rating nor a 16 mm frame proves adequacy. Repeat for acceleration, reversals, and stationary belt tension.

3. Distance Derating: Keep the Reference Datum Consistent

A catalog may measure load position from the mounting face, bearing center, or shaft end. Copy that datum onto the RFQ drawing. A longer overhang increases the bending demand, but the manufacturer's distance-derating curve takes precedence over any generic equation.

For the idealized two-bearing model, an estimate that holds only the front-bearing reaction constant is:

Fallow(x) = Fref × (b + xref) / (b + x)

Here x and xref are both measured from the front bearing center. If a drawing instead gives distance s from the mounting face, and the bearing center is a distance a behind that face, use x = a + s and xref = a + sref. Do not substitute face distances without accounting for the offset.

The table below uses assumed b = 6 mm, xref = 5 mm, and Fref = 20 N. It illustrates the arithmetic only; it is not a rating for any frame size or bearing architecture.

Load distance x from front bearing center (mm)Front-reaction-limited estimate (N)Relative to assumed reference
520.00100.0%
815.7178.6%
1013.7568.8%
1212.2261.1%
1610.0050.0%
208.4642.3%

This estimate does not preserve a rear-bearing limit, shaft fatigue limit, or allowable gear misalignment. It also omits combined thrust and internal gear forces. Do not extrapolate it into a product guarantee or use it to increase a published rating for a shorter overhang.

4. Bearing Architecture Comparison: Bushing vs. Ball Bearings

Bearing architecture informs the questions to ask; it cannot supply a universal force rating. Compare these options only after the supplier has confirmed the shaft, retention, housing, lubrication, and duty-cycle requirements.

Engineering parameterSintered sleeve bushingFront ball bearing + rear bushingDual deep-groove ball bearingsDedicated thrust / angular-contact arrangement
Radial loadVerify pressure, sliding speed and wear limitFront bearing may carry much of the external loadCheck reactions at both bearingsDepends on bearing type and arrangement
Axial loadNeeds a defined thrust surface or separate supportVerify retention and direction of supportVerify fits, shoulders and push/pull limitsDesigned around specified thrust directions
Clearance and runoutAsk for initial and worn clearance limitsCheck both bearing locationsAsk for assembled runout; bearing grade alone is insufficientPreload and assembly tolerances matter
LubricationOil supply and operating conditions affect wearCheck the bushing as well as the ball bearingSpecify lubricant, seals and temperature rangeCheck lubricant and preload heating
Life evidenceUse application wear/endurance testingAssess bushing wear and rolling fatigue separatelyBearing fatigue calculation plus assembly testingInclude preload, stiffness and combined-load evaluation
Cost evidenceRequest a quote for the specified assemblyQuote the complete bearing/shaft changeInclude assembly and inspection costsInclude preload control and inspection costs
Approval basisMeasured wear and function under the load cycleVerified assembled load path and enduranceSupplier load limits plus test evidenceSupplier analysis and application validation

ISO 281:2007 concerns rolling-bearing dynamic ratings and rating life, including the basic life associated with 90% reliability. It does not provide a sleeve-bushing life model or guarantee complete gearmotor service life; wear, corrosion, and electrical erosion are outside its stated life scope. Ask the supplier to distinguish a bearing fatigue estimate from measured assembly endurance.

5. Output Shaft and Frame Size: What a Buyer Must Request

There is no defensible N20, 16 mm, or 22 mm load limit based on outside diameter alone. FAULHABER's small gear motor selection overview includes permissible axial and radial shaft loads among the selection parameters, rather than deriving them from size or torque.

Use this evidence matrix for each shortlisted part number:

Required supplier evidenceWhat it must identifyHold the selection if…
Radial limitPermissible external force, load position and datumOnly torque or bearing component ratings are given
Push/pull thrust limitsDirection, running/stationary condition, retention designA single unexplained axial number is provided
Combined loadingSimultaneous radial/thrust envelope or approved load casesSeparate maxima are treated as simultaneously available
Shaft drawingDiameter, material, flats/grooves, shoulders and load centerFrame size substitutes for the shaft geometry
Speed and dutyOutput speed, motion cycle, starts, reversals and peaksA rating at a different operating condition is reused
Life basisRequired hours/cycles, reliability basis, test or calculation methodA bearing life number is presented as a gearbox warranty
Environment and assemblyTemperature, lubrication, contamination and press-fit restrictionsInstallation or exposure conditions are omitted

For application examples, consult the OEM drive solutions; for validation requirements, review quality and compliance documentation. Request part-specific evidence rather than transferring ratings between product families.

6. How Shaft Deflection Can Damage Internal Gear Stages

Output shaft tilt can change gear alignment and concentrate tooth contact. In many planetary designs the shaft connects to the output carrier; in a spur gearbox it connects to the final driven gear. The actual force path depends on the design.

Illustration of aligned and edge-loaded gear contactSchematic comparison of contact across a gear face and concentrated contact near an edge when a shaft tilts. The illustrated angle and stress colors are qualitative.Aligned Shaft: Full Face ContactDistributed contactFull tooth width shares load evenlyDeflected Shaft: Edge LoadingLocalized edge contactHigher local stress; inspect alignment

Figure 2. Qualitative illustration; no universal tilt angle or stress multiplier is implied.

There is no universal shaft-tilt failure angle, contact-stress multiplier, or time-to-failure for all micro gearboxes. Geometry, tooth modifications, material, fit, housing stiffness, and operating load affect the outcome. Inspect contact patterns and bearing seats, and assess shaft deflection together with transmitted torque. A stripped gear alone cannot prove which mechanism caused the failure.

7. Mechanical Troubleshooting: Diagnosing Shaft and Bearing Failures

Use these as hypotheses during lab testing or RMA analysis, not as diagnoses from symptoms alone. Record the original shaft play, loading conditions, current, temperature, and noise before endurance testing.

Observed symptomPossible causesVerification checkCorrective action to evaluate
Radial play grows during testingBushing wear, damaged bearing, loose housing fitCompare play at a defined measuring force; inspect support surfacesReduce side load/overhang or revise the support system
Final-stage teeth stripOverload, edge contact, material or lubrication issueInspect fracture and contact pattern; compare load/current historyAssess alignment and torque peaks before changing gear material
Noise increases under side loadBearing damage, gear mesh error, contaminationCompare unloaded and loaded noise; inspect bearings and gearsCorrect the confirmed load path, lubrication or fit issue
Stalls under push thrustCarrier rubbing, preload change, process obstructionApply controlled thrust within approved limits; inspect rubbing marksRevise thrust support or process load after confirming the cause
Shaft fractures near a shoulderBending fatigue, overload, notch effect or material defectInspect fracture origin and drawing; check actual force historyReassess shaft geometry, material and external support
Axial float exceeds the drawingRetention issue, tolerance stack or wearMeasure at a specified push/pull force; inspect retentionCorrect tolerance and retention design; do not add preload blindly

Further selection material is available in the technical library. Preserve sample identity and test conditions so a supplier can reproduce the failure investigation.

8. OEM Procurement Checklist: Specifying Shaft Loads in Your RFQ

Include these eight items in the drawing pack and obtain a written supplier response for the exact assembly revision:

  • 1. Load geometry: Dimension the radial load center from a named datum, include tolerances, and identify the shaft orientation and attached component weight.
  • 2. Radial load cycle: State working and peak forces in N, direction, duration, belt installation tension, and the transmission calculation method.
  • 3. Axial load cycle: State continuous and peak push/pull forces separately, including reversals, shocks and assembly press-fit loads.
  • 4. Combined-load cases: Provide simultaneous torque, radial force and thrust at output speed; request an approved envelope or written case-by-case assessment.
  • 5. Shaft and bearing interface: Provide drawing revision, shaft retention, runout and end-play acceptance limits measured at defined forces; ask the supplier to select a suitable bearing arrangement.
  • 6. External support and assembly: Show couplings/support bearings and their alignment tolerances; obtain an approved press-fit procedure that avoids an unintended bearing load path.
  • 7. Life and acceptance test: Specify hours or cycles, sample count, reliability objective, and pass/fail limits for wear, play, noise, current and function. Distinguish calculated bearing life from assembly test results.
  • 8. Duty, environment and sourcing: Provide starts/reversals, temperature, exposure, lubricant constraints, sample quantity, annual volume, destination and change-control requirements.

9. Frequently Asked Questions

Frequently Asked Questions

10. Request a Part-Specific Shaft-Load Review

Before committing to tooling, send your load case and drawing for an OEM engineering review. Include the eight checklist items above and ask for the rated load position, simultaneous radial/thrust allowance, assembly restrictions, and validation plan for the proposed part number.

Treat bearing upgrades, custom shafts, and outboard supports as design options to assess and quote. Confirm their feasibility, limits, cost, and test evidence for your assembly before accepting a production specification.

Sources & Technical References

Sources checked October 29, 2026. These support the stated principles; they do not certify the hypothetical examples or establish Micro Gear Motor OEM product ratings.

  1. Portescap — The Impact of Torque, Radial, and Axial Loads on Motor Selection: bearing choice, load position, dynamic thrust direction, and press-fit load paths.
  2. FAULHABER — Small gear motor: selection parameters, including allowable axial and radial shaft loads. This overview does not provide numerical load limits or deflection thresholds.
  3. Oriental Motor — Motor Sizing Basics Part 4: How to Calculate Radial Load and Axial Load: transmission forces, belt tension, load position and application coefficients. Its product examples are not ratings for miniature OEM gearboxes.
  4. ISO — ISO 281:2007, Rolling bearings: Dynamic load ratings and rating life: public scope and reliability basis for rolling-bearing rating life. The public abstract supports the scope discussion here; no claim is made to have validated this assembly against the full standard.

Inquiry Email

[email protected]

Include target torque/speed, quantity, and delivery location.

Instant Chat

WhatsApp Engineering Support

Routed to sales engineering for RFQ follow-up.