100:1 Micro Planetary Gear Motor
Estimate loaded speed and current; check exact-model limits before an OEM review.
100:1 operating-point estimate
Fixed-voltage brushed DC · Illustrative inputs
Illustrative 6 V Coreless Planetary — illustrative baseline, not a formal OEM guarantee
- Requested torque
- 450 gf·cm
- Requested torque in SI units
- 44.13 mN·m
- Modeled torque (capped at stall)
- 450 gf·cm
- Delivered output power
- 0.498 W
- Electrical power draw
- 1.425 W
- Motor power loss estimate
- 0.713 W
- Gearbox friction loss
- 0.214 W
- Total system efficiency
- 35%
- Modeled stall margin
- 4.36×
- Backdrive breakaway torque
- Unknown — exact assembly test required
- Mean stage reduction (illustration)
- 4.642:1 across 3 stages
- Continuous output torque — Needs verification: Unknown — request exact planetary gearhead continuous/peak ratings and duty cycle.
- Peak intermittent torque — Needs verification: Unknown — request exact planetary gearhead continuous/peak ratings and duty cycle.
- Shaft radial load — Needs verification: Unknown — enter both applied load (0 if none) and the documented rating at the same distance from the mounting face. Axial load and bearing life are not checked.
- Equal-share illustration — Needs verification: 3 planets: ideal carrier torque contribution 150 gf·cm each, based on modeled torque 450 gf·cm. Actual sharing is unknown. This is not tooth mesh force, a Kγ estimate, or a strength check.
- Gearhead input-speed rating — Needs verification: Modeled motor speed 10,785.71 RPM. The gearhead maximum input speed is not checked. Confirm continuous and startup speed limits for the exact assembly.
- Thermal duty & winding temperature — Needs verification: Not evaluated. Confirm rated motor current, winding temperature, ambient conditions and full duty cycle. Estimated power losses do not establish a temperature or life rating.
- Backdriving & unpowered holding — Needs verification: Breakaway torque is unknown and cannot be derived from forward efficiency or motor stall torque. Do not rely on unpowered gears for safety holding; review an independently rated brake or restraint.
Request exact motor and gearhead datasheets, input-speed and current ratings, dimensions and thermal/duty data. Qualify samples at worst-case supply, load and ambient conditions.
Preliminary fixed-voltage brushed DC linear model with assumed constant gearhead efficiency. Not a BLDC/controller model. Ignores gearbox idle drag, voltage sag and current limiting; zero-load speed/current are idealized. Efficiency at stall is not defined: the stall ceiling is a screening extrapolation, not available rated torque. Does not calculate temperature, tooth force/strength, bearing life, backlash or backdrive breakaway torque. Entered ratings are user data, not independently verified. No continuous-duty, safety-holding or medical approval.
First recorded: · Substantive review: · Micro Gear Motor OEM
Engineering decision guide
1. Four decisions before choosing a 100:1 drive
| Conclusion | Evidence / basis | Boundary and action |
|---|---|---|
| Size at the loaded point | Default illustrative model: 107.9 RPM and 237.4 mA at 450 gf·cm. Method below. | Replace illustrative inputs with a matched bare-motor datasheet. |
| Ratio is not a torque rating | Published 10/1 variants differ by stage count, torque and efficiency; see reference table. | Request the exact motor and gearhead configuration, not a family maximum. |
| Planet count is not strength approval | Equal carrier torque contributions can be illustrated; real tooth force requires geometry. | Request load-sharing and strength evidence for shock or life requirements. |
| Holding and life remain unknown | The tool has no brake, thermal or endurance model. | Qualify the mechanism with independent holding protection where needed. |
Curve basis: Portescap — brushed DC motor characteristics. Configuration limits: FAULHABER Series 10/1 and 10/1 K datasheet, p. 1.
2. Model, assumptions and units
For a fixed terminal voltage, the tool approximates a brushed DC motor with linear speed–torque and current–torque curves. It is a steady running-point screen. It neither simulates startup nor predicts a BLDC/controller operating map. Portescap — brushed DC motor characteristics
T_motor = T_load / (i × η)
x = T_motor / T_stall
n_out = n_0 × (1 − x) / i; I = I_0 + (I_stall − I_0) × x
P_out = T_out [N·m] × n_out × 2π / 60; P_elec = V × I [A]
| Quantity / state | Interpretation | Boundary |
|---|---|---|
| 1 gf·cm | 0.0000980665 N·m = 0.0980665 mN·m | Force and torque are different quantities. |
| x < 1 | A modeled running point exists | This does not imply thermal or gearhead approval. |
| x ≥ 1 | Speed and delivered mechanical power clamp to zero | Current clamps to entered stall current. Requested torque is not delivered. |
| Zero load | Ideal motor no-load speed / ratio | Real gearhead drag is omitted; assembled idle speed/current require measurement. |
The model rejects input curves that generate more mechanical than electrical power anywhere on the modeled curve. Passing that check is necessary but cannot validate the datasheet. For a fixed ring, sun input and carrier output, a simple stage has i = 1 + Z_ring/Z_sun. A total ratio alone does not determine tooth counts or assembly feasibility.
3. Planet sharing: what the illustration means
The result shows T_out/N as an ideal contribution to carrier torque for N planets. It is not tangential tooth force. Pin errors, stiffness, tooth contact and member constraints affect actual sharing; planet count alone cannot determine Kγ. No Kγ or fatigue safety factor is inferred.
| Final-stage planets | Ideal carrier torque contribution | Unknowns |
|---|---|---|
| 3 | 150 gf·cm per contribution | Geometry, actual sharing, tooth stress and bearing forces |
| 4 | 112.5 gf·cm per contribution | More planets do not prove higher allowable torque |
| 5 | 90 gf·cm per contribution | Carrier spacing and assembly feasibility not evaluated |
A tooth-bending assessment needs gear dimensions, material and loading inputs within the applicable method scope. ISO 6336-3:2019 — tooth bending strength scope is a scope reference, not evidence that this estimator performs that assessment.
4. Efficiency sensitivity, not a universal percentage
The entered efficiency is a constant scenario assumption. Actual gearhead efficiency varies with speed, torque, stage count and configuration; maximum catalog efficiency is an operating-point limit. FAULHABER — Precision Gearheads Technical Information
| Assumed total efficiency | Loaded speed (RPM) | Motor current (mA) | Interpretation |
|---|---|---|---|
| 60% | 102.5 | 270.4 | Illustration only; no selected gearhead rating |
| 70% | 107.9 | 237.4 | Illustration only; no selected gearhead rating |
| 80% | 111.9 | 212.8 | Illustration only; no selected gearhead rating |
If three stage efficiencies were assumed to be 88%, 86% and 84%, their product would be 63.5712%. At 1.5 W mechanical input the respective losses would be 0.180, 0.1848 and 0.181632 W, leaving 0.953568 W. These are arithmetic assumptions, not measured stage data. Stage and planet counts do not automatically change the calculator efficiency.
5. Published reference models and architecture trade-offs
The following published references are adjacent ratios, not 100:1 substitutes or presets. They show why an exact part number matters. Source: FAULHABER Series 10/1 and 10/1 K datasheet, p. 1 (2026-07-28 edition, p. 1; checked November 10, 2026). Ratings belong only to those configurations.
| Reference | Exact ratio / stages | Continuous torque | Maximum efficiency | Gearhead length |
|---|---|---|---|---|
| 10/1, Ø10 mm | 64:1 / 3 | 54 mN·m | 70% | 15.9 mm |
| 10/1, Ø10 mm | 256:1 / 4 | 100 mN·m | 60% | 19.0 mm |
| Architecture | Packaging / reason to consider | Qualification trade-off |
|---|---|---|
| Planetary | Coaxial drive; multiple planet load paths | Exact stage configuration, sharing, noise and life evidence needed |
| Parallel-shaft spur | Offset shaft can suit a flat enclosure | Compare exact ratings and integration cost; no universal torque disadvantage assumed |
| Worm / right-angle | Right-angle packaging | Efficiency and reverse behavior are geometry-dependent; no automatic safety holding approval |
6. Thermal duty and motor qualification
Estimated motor and gearhead losses are power balances, not temperatures. Winding resistance, thermal paths, mounting, ambient conditions and the full load-time cycle are missing. An entered gearhead torque rating cannot approve motor continuous current.
7. Radial load, axial load and load position
Compare radial load only with a rating at the same distance from the mounting face. Enter both values; enter 0 N explicitly for no applied radial load. The tool does not infer axial capacity, bearing reactions or service life. See the exact-model limits in FAULHABER Series 10/1 and 10/1 K datasheet, p. 1.
| Variant | Output bearing | Radial limit at 5 mm | Axial limit | Life result here |
|---|---|---|---|---|
| 10/1 | Sintered bearing | ≤ 1 N | ≤ 2 N | Unknown — no life calculation |
| 10/1 K | Preloaded ball bearing | ≤ 7 N | ≤ 5 N | Unknown — no life calculation |
For an ideal two-support shaft with load F a distance a beyond the front support and bearing span b, static equilibrium gives front reaction magnitude F(a+b)/b and rear magnitude Fa/b in the opposite direction. The distance a is measured from the front support, not automatically from the mounting face. Bearing fatigue needs further data; ISO 281:2007 — rolling bearing ratings and life scope does not establish plain-bushing wear life.
8. Encoder resolution and mechanical lost motion
Illustrative counting convention: a 16-cycle encoder with four-edge quadrature decoding and exact 100:1 reduction produces 6,400 edges per output revolution. Resolution is 360/6,400 = 0.05625° per edge. This is not positioning accuracy.
| Assumed backlash | Equivalent encoder edges | Next check |
|---|---|---|
| 0.5° | 8.89 | Measure output reversal under load |
| 1.0° | 17.78 | Check compliance and repeatability |
| 2.5° | 44.44 | Consider output feedback or preloading |
A motor encoder can register movement while backlash is being taken up. Firmware compensation depends on repeatable mechanics; preload can add drag and wear. Request output-side repeatability evidence instead of selecting by encoder counts alone.
9. Power-off holding and backdrive limits
Breakaway torque is unknown. Forward efficiency, stall torque and ratio do not establish static holding resistance. Lubrication, temperature, motor cogging, wear, driver terminal state and the load mechanism matter. No numeric holding threshold is provided.
10. Manufacturing, acoustics and lubrication evidence
| Choice | Potential benefit / trade-off | Evidence still needed |
|---|---|---|
| Machined metal gears | Geometry and tolerance flexibility; setup and finishing cost | Actual tooth inspection, material/heat treatment, tooling quote and endurance result |
| MIM or powder metallurgy | Potential volume economics; process-specific tooling and material behavior | Density, shrinkage control, finishing, fatigue tests and itemized tooling cost |
| Polymer first stage | Possible acoustic benefit with temperature and stiffness trade-offs | Matched-condition acoustic tests and torque/life qualification |
| Lubricant / fill amount | Cold-start drag, compatibility and long-term wear trade-offs | Supplier compatibility approval, fill specification, hot/cold current and endurance tests |
No matched public evidence is provided for this custom assembly’s dBA reduction, fatigue stress, grease fill percentage, cold-start current or tooling price. These remain unknown. Compare acoustic results only at the same load, speed, distance and mounting; ask for test conditions with every number.
11. Three reproducible operating-point cases
These are computed scenarios using the visible default inputs, not tested customer cases, clinical results or qualified motor selections. Restore the 6 V preset and change only required output torque to reproduce them.
Light running load
Assume a steady 450 gf·cm load and the default 6 V bare-motor curve. Gearhead ratings are unknown.
- Loaded speed
- 107.9 RPM
- Motor current
- 237.4 mA
Request exact motor and gearhead datasheets, input-speed and current ratings, dimensions and thermal/duty data. Qualify samples at worst-case supply, load and ambient conditions.
Open tool; enter 450 gf·cmHigh running load
Keep the same curve and raise load to 1,400 gf·cm. No shock or current limit is modeled.
- Loaded speed
- 40 RPM
- Motor current
- 654.3 mA
Request exact motor and gearhead datasheets, input-speed and current ratings, dimensions and thermal/duty data. Qualify samples at worst-case supply, load and ambient conditions.
Open tool; enter 1400 gf·cmStall screening
Raise the requested load to 2,200 gf·cm. This exceeds the extrapolated ceiling, so there is no running solution.
- Loaded speed
- 0 RPM
- Motor current
- 900 mA
Reduce load or select a motor/ratio with a feasible running point. Check gearhead limits and driver current protection before testing; the stall extrapolation is not a permissible operating rating.
Open tool; enter 2200 gf·cm
For an infusion application, a shaft torque estimate does not determine dose delivery accuracy, occlusion protection or regulatory compliance. IEC 60601-2-24:2012 — infusion pump safety and performance scope describes device-level requirements; no pump test data are claimed here.
12. Misuse, cost and application-fit risks
| Risk / trigger | Consequence | Mitigation / alternative |
|---|---|---|
| Use stall torque as continuous rating | Overheating or gear damage | Obtain motor thermal and gearhead duty limits; reduce load or change drive size |
| Size from nominal ratio only | Wrong loaded speed or package fit | Confirm actual ratio, input speed and dimensioned drawing |
| Assume planet count proves strength | Unexpected tooth or carrier failure | Request exact strength evidence and shock tests; consider a torque limiter |
| Ignore side load or load position | Shaft/support wear and misalignment | Review bearing/shaft system; add an outboard support |
| Choose by headline unit price | Tooling, finishing and validation exceed budget | Quote tooling, samples, inspection and acceptance tests separately |
| Require low noise or precise reversals | Standard drive may miss device targets | Benchmark at matched conditions; consider different feedback or transmission |
| Assume self-holding on power loss | Payload movement | Review independent rated restraint and mechanism-level fault tests |
13. OEM RFQ and acceptance checklist
| Category | Send with the inquiry | Decision enabled |
|---|---|---|
| Electrical | Supply range, bare-motor curve revision, driver/current limits | Loaded point and motor/driver compatibility |
| Mechanical | Running, peak and shock torque; speed; full load-time cycle | Motor and gearhead duty review |
| Integration | Shaft/mount drawing, radial/axial forces and load distances | Packaging, support and bearing selection |
| Environment | Temperature, noise conditions, life target and holding faults | Qualification plan and acceptance tests |
| Commercial | Sample/annual quantity, target date, tooling and inspection needs | Configuration-specific quote, MOQ and delivery confirmation |
RFQ Intake
Request an Exact-Model Engineering Review
Send your worksheet, load profile and drawing so engineering can review a suitable motor, gearhead and qualification plan.
14. Engineering and sourcing FAQs
[Sizing]What speed does a 100:1 micro planetary gear motor deliver?
At an exact 100:1 ratio, 14,000 motor RPM becomes 140 output RPM before load. With the illustrative default curve and 450 gf·cm load, the model gives 107.9 RPM. Neither value is a continuous-duty rating.
[Sizing]Which torque belongs in the motor stall field?
Enter bare-motor stall torque before reduction at the same voltage as all other motor inputs. A finished gearmotor output torque would multiply the ratio twice. If only assembly data are available, request the matching bare-motor curve.
[Sizing]Does changing voltage rescale the motor curve?
No. Voltage is used for electrical power only. Replace speed, current and torque data together with values documented at the new terminal voltage. Supply sag and driver current limiting require separate review.
[Sizing]Can I use BLDC or closed-loop controller data?
This tool uses a brushed DC linear approximation. BLDC phase current, bus current and controller-limited stall behavior are not interchangeable. Use a manufacturer motor/controller operating map for those systems.
[Planetary mechanics]Is every nominal 100:1 ratio exactly 100?
No. Use the exact tooth-count ratio supplied for the selected assembly. The geometric-mean stage ratio here is an illustration, not a manufacturable gear design.
[Planetary mechanics]Does adding planets increase the approved torque rating?
Not automatically. More paths can distribute load, but pin accuracy, member stiffness and geometry determine real sharing. The equal-share carrier torque illustration is not a tooth force or strength check.
[Planetary mechanics]Does stage count change efficiency in this tool?
No. Stage count changes only the geometric-mean ratio illustration. Enter total operating-point efficiency separately; the tool does not infer it from planet count or stage count.
[Limits]Can the result approve continuous operation?
No. Even a result within all entered limits still needs motor current, input-speed, winding-temperature, duty-cycle, axial-load and assembly-life qualification. The tool has no thermal or endurance model.
[Limits]What should I do with a stall result?
Reduce the load or choose a different motor/ratio. Review gearhead torque and current protection before a sample test. The constant-efficiency stall extrapolation is not a permissible load rating or a holding-torque rating.
[Limits]What does a blank optional rating mean?
Unknown, never zero or unlimited. Enter both radial load and its documented limit at the same load distance; enter 0 N explicitly when there is no radial load. Missing values keep the overall result unverified.
[Integration]Does a motor encoder remove backlash?
No. Encoder count resolution and mechanical lost motion are different. For an illustrative 16-cycle quadrature encoder at 100:1, 6,400 edges per output turn give 0.05625 degrees per edge; measure output reversals under load separately.
[Integration]Can the planetary gearbox hold a suspended load without power?
Do not assume it can. Breakaway torque is unknown here and cannot be derived from forward efficiency. Review a rated power-off brake or independent restraint for the actual mechanism.
[Integration]Which bearing construction should I specify?
Use the exact radial and axial ratings, load position, speed and life requirement. Bearing type alone cannot establish capacity; an outboard support may be needed for a pulley or wheel.
[Integration]Does this tool establish medical device compliance?
No. Flow accuracy, occlusion behavior, alarms and device safety require system-level evidence. No clinical, regulatory or IEC conformity result is produced.
[Sourcing]Can I get a fixed price, MOQ or lead time here?
No published quotation is attached to the illustrative examples. Submit quantities, drawing, material, test requirements and schedule to confirm price, tooling cost, MOQ and delivery for the exact configuration.
[Sourcing]What should I send with an engineering RFQ?
Download the worksheet and provide the source datasheet revision, load-versus-time profile, speed target, supply range, mounting drawing, shaft loads and application point, ambient conditions, quantity and acceptance tests.
15. Source register, dates and unresolved evidence
Checked November 10, 2026. Catalog values retain the cited edition and configuration. Standards links establish subject scope only; this page does not claim standards compliance. Reconfirm current editions and exact part revisions before release.
- Portescap — brushed DC motor characteristics
Supports a linear brushed DC speed–torque approximation; does not validate our illustrative inputs.
- FAULHABER Series 10/1 and 10/1 K datasheet, p. 1
Edition 2026-07-28. Exact ratios, stage count, torque, maximum efficiency, backlash and shaft-load limits for these models only; no 100:1 variant is listed.
- FAULHABER — Precision Gearheads Technical Information
PDF pp. 11 and 13: efficiency depends on operating point; continuous, intermittent and peak limits have distinct conditions. These are not interchangeable ratings.
- ISO 6336-3:2019 — tooth bending strength scope
Tooth-bending calculation reference with defined applicability; no calculation or conformity assessment is performed here.
- ISO 281:2007 — rolling bearing ratings and life scope
Rolling-bearing life methodology, not a plain-bushing wear model or a gearmotor service-life guarantee. Confirm the applicable edition before a formal assessment.
- IEC 60601-2-24:2012 — infusion pump safety and performance scope
Device-level requirements. A motor choice or this sizing calculation cannot establish pump compliance or flow accuracy.
Known / unknown boundary
Known: tool equations, explicit input assumptions and the cited reference-model ratings. Unknown for a custom 100:1 assembly: actual efficiency map, Kγ, tooth strength, backlash, backdrive threshold, thermal limits, noise, service life, unit price, tooling, MOQ and lead time. Obtain exact-model evidence and sample tests before committing requirements.
Preliminary fixed-voltage brushed DC linear model with assumed constant gearhead efficiency. Not a BLDC/controller model. Ignores gearbox idle drag, voltage sag and current limiting; zero-load speed/current are idealized. Efficiency at stall is not defined: the stall ceiling is a screening extrapolation, not available rated torque. Does not calculate temperature, tooth force/strength, bearing life, backlash or backdrive breakaway torque. Entered ratings are user data, not independently verified. No continuous-duty, safety-holding or medical approval.