100:1 Micro Worm Gear Motor
Estimate loaded speed, operating current, sliding friction heat, and entered gearhead limits for 90° right-angle motion.
Live sizing tool
Illustrative brushed DC inputs. Holding capacity and thermal duty remain unverified.
Illustrative 6 V Right-Angle N20 Worm Motor — illustrative baseline, not a formal OEM guarantee
- Requested load torque
- 500 gf·cm
- Requested torque in SI
- 49.03 mN·m
- Modeled torque at shaft
- 500 gf·cm
- Mechanical output power
- 0.342 W
- Electrical input power
- 3.367 W
- Sliding friction heat loss
- 0.418 W
- Aggregate motor loss
- 2.606 W
- Stall safety factor
- 2.25×
- Worm wheel teeth (z2)
- 100 teeth
- Thread lead angle (γ)
- 4.5°
First recorded: · Substantive review: · Micro Gear Motor OEM
1. Decision summary: calculate first, qualify next
Use the tool to screen a fixed-voltage brushed DC running point. Use this guide to decide which data and tests are still needed before choosing a 100:1 micro worm gear motor.
| Decision | Known from the model | Unknown / next action |
|---|---|---|
| Speed and current | 66.67 RPM and 561.11 mA at 500 gf·cm | Verify the actual motor curve and efficiency; see method and Portescap reference |
| Gearhead capacity | Only explicitly entered torque and external load limits are compared | Request matched manufacturer ratings; see capacity scope |
| Holding | Ratio and lead angle identify geometry only | Obtain reverse-load tests; see KHK and maxon references |
| Thermal duty | 0.418 W modeled gearbox loss | Allowable duty and temperature require enclosure tests; see thermal section |
Reproduce the calculation · Check source scope · Request missing engineering data
2. Reproducible model, assumptions and units
All motor inputs describe the same bare brushed DC motor at one terminal voltage. Portescap describes the linear torque–speed characteristic; the constants here are illustrative. A BLDC/controller map, compound gearbox or measured efficiency curve needs a separate model. Changing voltage alone does not rescale the motor data.
Portescap — Brushed DC Motor Basics
| Quantity | Calculation | Limitation |
|---|---|---|
| Reflected torque | Tm = Tload / (i × η) | Constant running efficiency assumption |
| Load fraction | f = Tm / Tstall | Running solution only for 0 ≤ f < 1 |
| Output speed | n_out = n0 × (1 − f) / i | RPM; idealized at zero load |
| Current | I = I0 + f × (Istall − I0) | mA at the specified terminal voltage |
| Output power | Pout = (2π × n_out / 60) × Tload × 9.80665e−5 | Watts; 1 gf·cm = 9.80665e−5 N·m |
| Stall ceiling | Tstall × i × η | Running-efficiency extrapolation, not a rated torque |
| Energy guard | K = (2πn0/60) × Tstall × 9.80665e−5; Pmech = Kf(1−f) | Reject a curve if mechanical power exceeds V × I(f)/1000 anywhere in [0,1] |
The energy guard rejects impossible inputs but cannot verify real motor behavior. Startup, idle gearbox drag, current limiting, voltage sag and thermal transients are omitted. Zero-loss gear motion at stall does not mean zero electrical heating.
| Example | Load (gf·cm) | Loaded RPM | Current (mA) | Stall ceiling (gf·cm) |
|---|---|---|---|---|
| 6 V | 500 | 66.67 | 561.11 | 1125 |
| 12 V | 750 | 68.57 | 478.78 | 1470 |
| 24 V | 1100 | 73.61 | 371.2 | 2160 |
3. Geometry and right-angle packaging
The exact ratio sets speed reduction; it does not establish torque capacity or holding. For a single worm stage, i = z2 / z1. Check the assembled drawing before assuming the nominal ratio or envelope.
Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.
| Geometry input | Decision it enables | Evidence to request |
|---|---|---|
| Ratio and starts | 100:1 with one start implies 100 wheel teeth | Tooth counts and number of stages |
| Lead angle | Records thread geometry; no holding classification | Approved worm drawing |
| Pitch diameter | Enables 2T/d thrust estimate | Wheel pitch diameter, not outside diameter |
| 90° shaft axes | May help a shallow housing fit | CAD envelope with motor length and cable bend |
| Compound reduction | Tool tooth-count inference is unsuitable | Stage ratios and individual mesh geometry |
4. Load capacity: what the tool cannot rate
A running point is not a tooth-strength or wear calculation. As of the November 10, 2026 review, ISO 14521:2026 replaces ISO/TS 14521:2020. Its public scope requires special treatment for center distances below 50 mm; do not transfer large-drive capacity rules to a micro assembly.
Reference scope: ISO 14521:2026 — Gears: Calculation of load capacity of worm gears.
| Failure mode | Missing information | Minimum validation action |
|---|---|---|
| Wear and pitting | Geometry, material and lubrication data | Obtain a specialist load-capacity calculation |
| Tooth breakage | Root geometry and load spectrum | Review transient and reversing torque |
| Worm deflection | Shaft span, section and support stiffness | Check mesh alignment under load |
| Thermal limit | Thermal path and allowable temperatures | Instrument the assembled enclosure |
| Scuffing | Not covered by the cited ISO public scope | Request a separate tribology assessment |
5. Efficiency, power balance and energy checks
Efficiency is a user assumption. The 45% default is an illustrative operating value, not an OEM rating. KHK publishes efficiency estimates for identified stock pairs and notes dependence on assembly, load, lubrication and speed; those data cannot validate this micro assembly.
Reference scope: KHK — Worm Gears technical catalog (2023).
| Output | Definition | How to use it |
|---|---|---|
| Motor mechanical power | Tm × motor angular speed | Before gearbox losses |
| Shaft output power | Tload × output angular speed | Useful running mechanical power |
| Gearbox loss | Motor mechanical power minus shaft power | Estimated loss at the chosen operating point |
| Aggregate motor loss | Electrical input minus motor mechanical power | Includes losses beyond copper heating |
| Energy validation | Pmech(f) ≤ V × I(f) over 0 ≤ f ≤ 1 | Rejects impossible curves; passing does not prove accuracy |
6. Holding and reverse-drive uncertainty
Holding remains unverified for every lead angle in this tool. KHK identifies multiple self-locking factors and recommends another braking mechanism when complete reverse prevention is required. maxon separately explains why reverse behavior must be evaluated on the complete drive.
Reference scope: maxon — Gears: Self-locking or back drivability (updated March 2026).
| Condition | What remains unknown | Action |
|---|---|---|
| Power off, steady load | Reverse breakaway torque | Measure both directions within gearhead ratings |
| Vibration or impact | Change in reverse behavior | Test the application disturbance profile |
| Cold/hot lubricant | Friction and breakaway variation | Repeat at temperature extremes |
| Critical suspended or retained load | Consequence of creep or release | Specify independently rated retention |
| Running stall ceiling | Not a holding or brake rating | Do not convert it into allowable retained load |
7. Compare architectures before committing
These are engineering comparison questions rather than measured rankings. Compare real candidate drawings and curves at the same shaft load and duty.
| Architecture | Reason to investigate | Tradeoff to verify |
|---|---|---|
| Right-angle worm | Orthogonal axes may suit shallow packaging | Sliding losses, reverse behavior and worm support |
| In-line planetary | Coaxial motor and output | Axial length, load distribution and reverse behavior |
| Parallel spur | Alternative shaft arrangement | Stage count, envelope and measured noise |
| Separate brake/lock | Documented holding function | Added space, actuation power and cost |
8. Internal worm thrust versus external shaft loads
For an orthogonal pair, wheel tangential force gives the worm axial reaction magnitude: Fa1 = Ft2 = 2 × T2 / d2, using N·m and meters. At 500 gf·cm and an explicitly assumed 15 mm pitch diameter, this is 6.54 N. The calculator requires your actual pitch diameter; the default is unknown.
Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.
| Load path | What the calculator does | What it cannot approve |
|---|---|---|
| Internal worm axial reaction | Estimates 2T/d when pitch diameter is entered | Worm bearings, washers or housing support |
| External output radial load | Compares entered load and rating | Load position, bending and combined bearing life |
| External output axial load | Compares entered load and rating | Internal worm support or combined bearing life |
| Reversal and shock | Steady magnitude only | Impact, preload, end-float and fatigue |
9. Materials and manufacturing cost risks
Do not choose a material from nominal ratio alone. Request a documented worm/wheel pair and a drawing-based process plan. The page has no verified hardness, roughness, fatigue life or manufacturing cost data for a custom unit.
Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.
| Choice | Information required | Risk mitigation |
|---|---|---|
| Metal worm and bronze wheel | Alloy, heat treatment, finish and lubricant | Review wear and compatibility together |
| Polymer wheel | Resin grade, temperature, creep and lubricant compatibility | Test retained load and thermal cycling |
| Cut, rolled or ground worm | Geometry, volume, tolerances and inspection | Quote the required process and tooling separately |
| Tighter backlash target | Preload, clearance and thermal tolerance | Compare friction and reversal repeatability |
| Custom support or sealing | CAD changes and qualification scope | Confirm NRE, unit cost and sample schedule in writing |
10. Lubricant selection and cold-start testing
A lubricant must be selected for the actual gear pair. Klüber identifies ISOFLEX TOPAS NB 52 as a synthetic hydrocarbon/barium-complex bearing grease; that identity alone does not approve it for a particular worm drive. This page prescribes no universal additive, fill percentage or change interval.
Reference scope: Klüber — ISOFLEX TOPAS NB 52 product information.
| Condition | Ask the supplier | Check on the assembly |
|---|---|---|
| Low temperature | Approved viscosity and lubricant grade | Startup current, delay and achieved speed |
| High temperature | Lubricant and seal compatibility limits | Housing and winding temperature |
| Polymer gears or seals | Material compatibility evidence | Swelling, embrittlement and wear |
| Fill quantity | Assembly-specific quantity and location | Drag, distribution and leakage |
| Maintenance interval | Lubrication life evidence | Inspect wear and lubricant condition |
11. Duty cycle and enclosure qualification
The tool estimates loss at one steady running point. It cannot derive a safe on-time or duty percentage. For repeated run/rest periods, duty fraction = run time / (run time + rest time); equal fractions can produce different peak temperatures when cycle lengths differ.
| Test variable | Why it matters | Record before release |
|---|---|---|
| Run/rest duration | Duty fraction alone hides peak heating | Full torque–speed–time cycle |
| Motor and gearhead losses | Both heat the assembly | Winding/housing temperature over the full cycle |
| Mounting and enclosure | Change the heat path | Actual bracket, shell and sealing |
| Supply and protection | Startup and jam behavior differ from steady state | Voltage at motor, current limit and cutoff time |
| Worst ambient | Alters temperature margin and lubricant drag | Cold start and hot duty tests |
12. Noise, backlash and acceptance criteria
No measured dBA, lost-motion, repeatability or lifetime value is published for these examples. Specify reproducible acceptance conditions before comparing candidate assemblies.
| Measurement | Control conditions | Decision criterion |
|---|---|---|
| Noise | Distance, background noise, speed, load and mounting | Application-specific limit agreed before samples |
| Backlash | Output angle at defined reversal torque | Measured lost motion at the actual load |
| Position repeatability | Encoder location and reversal cycle | Application tolerance across temperature |
| Wear drift | Cycle profile, lubricant and inspection intervals | Change from initial accepted measurements |
13. Three reproducible load scenarios
These are hypothetical arithmetic examples, not customer installations or certified application results. All use the default 6 V, 12,000 RPM, 25 gf·cm stall torque, 50/1,200 mA no-load/stall current, 100:1 ratio and 45% efficiency. Copy each load into the tool to reproduce it.
| Required load (gf·cm) | RPM | Current (mA) | Gearbox loss (W) | Interpretation and action |
|---|---|---|---|---|
| 500 | 66.67 | 561.11 | 0.418 | Complete both torque ratings and both external load/rating pairs (enter zero only for a known zero load). Missing data remains unverified. Request supplier ratings or send the worksheet for review. |
| 950 | 18.67 | 1021.11 | 0.223 | Stall margin is at or below the illustrative 1.5× review threshold, not a standard safety factor. Validate startup, voltage sag and cold lubricant behavior on the actual assembly. |
| 1300 | 0 | 1200 | 0 | No running point at or above the modeled stall ceiling. Reduce load or select a different motor/ratio. Any voltage change requires a complete matched motor curve and controller review. |
| Application | Missing decision data | Next qualification step |
|---|---|---|
| Latch actuator | Bolt force, linkage arm, jam torque and independent retention | Map force to shaft torque and test jams; no security grade claimed |
| Metering mechanism | Lead-screw efficiency, required flow accuracy and device hazards | Perform device-level verification; no medical approval |
| Outdoor positioner | Wind torque, exposure, sealing and retained-load requirement | Test environmental behavior and retention; no IP or wind rating claimed |
14. Frequently asked engineering & sourcing questions
[Sizing]What output speed does a 100:1 micro worm gear motor deliver?▼
[Sizing]Which torque belongs in the bare motor stall torque input?▼
[Sizing]Why does changing voltage not automatically change speed?▼
[Sizing]What happens when the load reaches the stall ceiling?▼
[Holding]Is a 100:1 micro worm gear motor completely self-locking?▼
[Holding]Can this tool calculate holding torque?▼
[Mechanics]Why does the worm shaft need an axial reaction check?▼
[Mechanics]Why is internal thrust shown as unknown?▼
[Mechanics]Can I enter an exact ratio different from 100:1?▼
[Thermal]Can gearbox loss determine a safe duty cycle?▼
[Lubrication]Which grease should I specify?▼
[Acoustics]Does a worm gear guarantee low noise or zero backlash?▼
[Limits]What does within entered limits mean?▼
[Limits]Can this tool approve a motor for medical infusion pump use?▼
[Sourcing]Are pricing, stock, and MOQ published on this page?▼
[Sourcing]What should I submit with an RFQ?▼
15. RFQ inputs and qualification evidence
| Input category | What to supply | What to confirm |
|---|---|---|
| Electrical | Matched motor curve, voltage range, supply and current limit | Startup, stall protection and controller compatibility |
| Motion | Running/peak torque, target speed and torque–time profile | Continuous and peak ratings with allowable durations |
| Interface | Shaft/mounting drawings, radial and axial loads plus locations | Exact ratio, pitch diameter and internal support capacity |
| Duty and environment | Run/rest cycle, ambient, enclosure, noise and retention targets | Thermal, reverse-load, wear and environmental test evidence |
| Commercial | Samples, annual volume, destination and requested schedule | Quotation, tooling cost, availability and agreed lead time |

Custom assembly noise, backlash, life, holding torque and allowable duty remain unknown until supplied or tested. No public standard scope or calculator result establishes those values for a specific build.
RFQ Intake
Request a Custom 100:1 Worm Engineering Review
Send the worksheet, matched motor datasheet, duty profile and shaft drawing. Request the missing ratings and an agreed qualification plan.
16. Evidence register and model boundaries
Sources checked November 10, 2026. Manufacturer guidance supports general principles; standards listings establish scope and edition only. Full paid standards were not used to certify these equations or any custom assembly. Example inputs, the 1.5× review threshold and application checklists are explicitly illustrative engineering assumptions.
- Portescap — Brushed DC Motor Basics — Manufacturer explanation of linear torque–speed behavior. Supports the approximation, not the illustrative motor inputs.
- KHK — Worm Gears technical catalog (2023) — Product-specific efficiency estimates and self-locking factors. Its stock gear data is not a rating for our custom micro assembly.
- maxon — Gears: Self-locking or back drivability (updated March 2026) — Explains why reverse behavior depends on the complete motor and gear combination; reverse loads must respect gearhead ratings.
- ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing — Public scope covers fine/coarse pitch right-angle cylindrical worm designs; D19 replaces C93. This tool does not implement its rating procedure.
- ISO 14521:2026 — Gears: Calculation of load capacity of worm gears — Public abstract covers wear, pitting, deflection, tooth breakage and temperature, excluding scuffing. Below 50 mm center distance it specifies method A. Full standard calculations are outside this tool.
- Klüber — ISOFLEX TOPAS NB 52 product information — A specific synthetic hydrocarbon/barium-complex bearing grease, not a universal micro-worm lubricant approval or gearbox temperature rating.
Model boundary: Preliminary fixed-voltage brushed DC linear model with assumed constant right-angle worm gear efficiency. Not a BLDC/controller model. Ignores gearbox idle sliding drag, voltage sag and current limiting; zero-load speed/current are idealized. Efficiency at stall is not defined: the stall ceiling is a screening extrapolation, not available rated continuous torque. Worm self-locking is a static friction property sensitive to vibration, shock, lubrication breakdown, and temperature; it is NOT an approved personal safety brake. Does not calculate internal gear tooth surface contact stress, thermal steady-state temperature rise, lubrication life, or bearing fatigue life. Entered ratings are user data, not independently verified. No continuous-duty, safety-holding or medical approval.