100:1 Micro Worm Gear Motor

Estimate loaded speed, operating current, sliding friction heat, and entered gearhead limits for 90° right-angle motion.

Live sizing tool

Illustrative brushed DC inputs. Holding capacity and thermal duty remain unverified.

Worm Gear Motor Input Controls

Steady running shaft load. Shocks, accelerations, and stalls must be checked separately against gearhead ratings. Range: 0–30000 gf·cm.

Output Speed
66.67 RPM
No-load: 120 RPM
Operating Current
561.11 mA
Power draw: 3.37 W
Modeled load torque
500 gf·cm
49.03 mN·m (0.049 N·m)
Overall Efficiency
10.2 %
Gearbox loss: 0.42 W (heat)
Ratings unverified — qualification required

Complete both torque ratings and both external load/rating pairs (enter zero only for a known zero load). Missing data remains unverified. Request supplier ratings or send the worksheet for review.

Holding / Self-LockingUnverified

Holding capacity unknown: lead angle alone cannot establish self-locking. Obtain reverse-load test data for the exact materials, lubrication, temperature and vibration. Use an independently rated brake or positive lock when holding is critical.

Worm Thrust & MechanicsLead: 4.5° · 1 start · 100T

Internal axial reaction thrust on worm shaft: Unknown — enter wheel pitch diameter. Verify internal support separately from external output shaft ratings.

Electromechanical parameters & worm gearhead limits (16 fields)Click to customize

Enter bare motor curve values before worm reduction. Do not enter output gearmotor ratings in motor fields. Worm sliding friction creates heat; enter verified continuous and peak limits from your supplier datasheet.

All motor parameters must be specified at this terminal voltage. Changing voltage alone does not rescale the curve. Range: 1–48 V.

Motor shaft speed before worm reduction. Do not enter output gearmotor speed. Range: 500–60000 RPM.

Motor idle current without gearbox load at specified voltage. Range: 0–2000 mA.

Bare motor stall torque before worm ratio multiplication. Range: 1–1000 gf·cm.

Motor stall current at the specified voltage. Must exceed no-load current. Range: 50–20000 mA.

Nominal 100:1. Enter exact kinematic stage tooth-count ratio when known (e.g. 100:1 for single-start worm with 100T wheel). Range: 10–500 :1.

Assumed constant efficiency, not a measured rating. Replace with supplier data for the exact load, speed and temperature. Range: 15–90 %.

Geometry only. Lead angle alone cannot determine self-locking without friction, lubrication and assembly test data. Range: 1–25 °.

Integer thread count. Ratio × starts must equal a whole wheel tooth count; 100:1 alone does not imply self-locking. Range: 1–4 starts.

Optional: actual pitch diameter, not outside diameter. Required for internal worm thrust estimate; blank means unknown. Range: 1–200 mm.

Optional: documented continuous rating for the worm gearhead. Leave unknown ratings blank; zero means a documented zero allowance. Range: 0–35000 gf·cm.

Optional: documented peak gearhead rating. Leave unknown blank. Does not check peak duration, cyclic loads, shock, or tooth strength. Range: 0–60000 gf·cm.

Optional: external side load on output shaft (from belts, pulleys, or side levers). Range: 0–120 N.

Optional: documented radial allowance at the actual load location. Leave unknown blank; zero means no radial load is permitted. Range: 0–150 N.

Optional: external axial pushing or pulling force on the output gear shaft. Range: 0–120 N.

Optional: documented output shaft axial allowance. Leave unknown blank; zero means no external axial load is permitted. Range: 0–150 N.

Request Custom OEM Worm Sizing Review

Illustrative 6 V Right-Angle N20 Worm Motor — illustrative baseline, not a formal OEM guarantee

100:1 Micro Worm Operating Point CurveNo-load speed (120 RPM)0 loadStall ceiling (1125 gf·cm)
Operating point (dot) relative to extrapolated worm stall ceiling. Worm gears must not be driven to stall continuously due to rapid sliding heat accumulation.
Requested load torque
500 gf·cm
Requested torque in SI
49.03 mN·m
Modeled torque at shaft
500 gf·cm
Mechanical output power
0.342 W
Electrical input power
3.367 W
Sliding friction heat loss
0.418 W
Aggregate motor loss
2.606 W
Stall safety factor
2.25×
Worm wheel teeth (z2)
100 teeth
Thread lead angle (γ)
4.5°
Engineering Verification Checks
warning
Self-locking & dynamic holding boundary:Holding capacity unknown: lead angle alone cannot establish self-locking. Obtain reverse-load test data for the exact materials, lubrication, temperature and vibration. Use an independently rated brake or positive lock when holding is critical.
warning
Sliding friction & thermal dissipation:Modeled gearbox loss is 0.42 W and motor loss is 2.61 W. Allowable run time and duty cycle are unknown without thermal ratings and enclosure tests. At stall, zero modeled gear motion does not imply zero motor heating.
warning
Worm shaft internal axial thrust reaction:Internal worm thrust is unknown. Enter the actual wheel pitch diameter, then verify the worm shaft support separately from output shaft axial ratings.
warning
Output shaft radial overhung load:External radial capacity is unverified. Enter both the applied load (zero only when known absent) and the documented rating at the actual load location.
warning
External output shaft axial thrust load:External output axial capacity is unverified. Enter both the applied load (zero only when known absent) and the documented output shaft axial rating.
Model Boundary & Safety Notice: Preliminary fixed-voltage brushed DC linear model with assumed constant right-angle worm gear efficiency. Not a BLDC/controller model. Ignores gearbox idle sliding drag, voltage sag and current limiting; zero-load speed/current are idealized. Efficiency at stall is not defined: the stall ceiling is a screening extrapolation, not available rated continuous torque. Worm self-locking is a static friction property sensitive to vibration, shock, lubrication breakdown, and temperature; it is NOT an approved personal safety brake. Does not calculate internal gear tooth surface contact stress, thermal steady-state temperature rise, lubrication life, or bearing fatigue life. Entered ratings are user data, not independently verified. No continuous-duty, safety-holding or medical approval.

First recorded: · Substantive review: · Micro Gear Motor OEM

1. Decision summary: calculate first, qualify next

Use the tool to screen a fixed-voltage brushed DC running point. Use this guide to decide which data and tests are still needed before choosing a 100:1 micro worm gear motor.

Known / unknown boundary — illustrative 6 V example, not product ratings · Scroll horizontally on small screens.
DecisionKnown from the modelUnknown / next action
Speed and current66.67 RPM and 561.11 mA at 500 gf·cmVerify the actual motor curve and efficiency; see method and Portescap reference
Gearhead capacityOnly explicitly entered torque and external load limits are comparedRequest matched manufacturer ratings; see capacity scope
HoldingRatio and lead angle identify geometry onlyObtain reverse-load tests; see KHK and maxon references
Thermal duty0.418 W modeled gearbox lossAllowable duty and temperature require enclosure tests; see thermal section

Reproduce the calculation · Check source scope · Request missing engineering data

2. Reproducible model, assumptions and units

All motor inputs describe the same bare brushed DC motor at one terminal voltage. Portescap describes the linear torque–speed characteristic; the constants here are illustrative. A BLDC/controller map, compound gearbox or measured efficiency curve needs a separate model. Changing voltage alone does not rescale the motor data.

Portescap — Brushed DC Motor Basics

Running-point equations — torque in gf·cm, current in mA, ratio i, efficiency η as a fraction · Scroll horizontally on small screens.
QuantityCalculationLimitation
Reflected torqueTm = Tload / (i × η)Constant running efficiency assumption
Load fractionf = Tm / TstallRunning solution only for 0 ≤ f < 1
Output speedn_out = n0 × (1 − f) / iRPM; idealized at zero load
CurrentI = I0 + f × (Istall − I0)mA at the specified terminal voltage
Output powerPout = (2π × n_out / 60) × Tload × 9.80665e−5Watts; 1 gf·cm = 9.80665e−5 N·m
Stall ceilingTstall × i × ηRunning-efficiency extrapolation, not a rated torque
Energy guardK = (2πn0/60) × Tstall × 9.80665e−5; Pmech = Kf(1−f)Reject a curve if mechanical power exceeds V × I(f)/1000 anywhere in [0,1]

The energy guard rejects impossible inputs but cannot verify real motor behavior. Startup, idle gearbox drag, current limiting, voltage sag and thermal transients are omitted. Zero-loss gear motion at stall does not mean zero electrical heating.

Preset results derived from the same calculation module — all inputs illustrative · Scroll horizontally on small screens.
ExampleLoad (gf·cm)Loaded RPMCurrent (mA)Stall ceiling (gf·cm)
6 V50066.67561.111125
12 V75068.57478.781470
24 V110073.61371.22160
From input to decisionCheck matched motor dataCalculate the running pointCompare documented limitsQualify the complete assembly
From input to decision. The worksheet is a screening record; it does not certify a product.

3. Geometry and right-angle packaging

The exact ratio sets speed reduction; it does not establish torque capacity or holding. For a single worm stage, i = z2 / z1. Check the assembled drawing before assuming the nominal ratio or envelope.

Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.

Geometry and right-angle packaging — decision checklist · Scroll horizontally on small screens.
Geometry inputDecision it enablesEvidence to request
Ratio and starts100:1 with one start implies 100 wheel teethTooth counts and number of stages
Lead angleRecords thread geometry; no holding classificationApproved worm drawing
Pitch diameterEnables 2T/d thrust estimateWheel pitch diameter, not outside diameter
90° shaft axesMay help a shallow housing fitCAD envelope with motor length and cable bend
Compound reductionTool tooth-count inference is unsuitableStage ratios and individual mesh geometry
Geometry and right-angle packaging workflowObtain the drawingIdentify each stageConfirm pitch geometryCheck housing clearance
Geometry and right-angle packaging workflow. Qualification actions; no performance guarantee is implied.

4. Load capacity: what the tool cannot rate

A running point is not a tooth-strength or wear calculation. As of the November 10, 2026 review, ISO 14521:2026 replaces ISO/TS 14521:2020. Its public scope requires special treatment for center distances below 50 mm; do not transfer large-drive capacity rules to a micro assembly.

Reference scope: ISO 14521:2026 — Gears: Calculation of load capacity of worm gears.

Load capacity: what the tool cannot rate — decision checklist · Scroll horizontally on small screens.
Failure modeMissing informationMinimum validation action
Wear and pittingGeometry, material and lubrication dataObtain a specialist load-capacity calculation
Tooth breakageRoot geometry and load spectrumReview transient and reversing torque
Worm deflectionShaft span, section and support stiffnessCheck mesh alignment under load
Thermal limitThermal path and allowable temperaturesInstrument the assembled enclosure
ScuffingNot covered by the cited ISO public scopeRequest a separate tribology assessment

5. Efficiency, power balance and energy checks

Efficiency is a user assumption. The 45% default is an illustrative operating value, not an OEM rating. KHK publishes efficiency estimates for identified stock pairs and notes dependence on assembly, load, lubrication and speed; those data cannot validate this micro assembly.

Reference scope: KHK — Worm Gears technical catalog (2023).

Efficiency, power balance and energy checks — decision checklist · Scroll horizontally on small screens.
OutputDefinitionHow to use it
Motor mechanical powerTm × motor angular speedBefore gearbox losses
Shaft output powerTload × output angular speedUseful running mechanical power
Gearbox lossMotor mechanical power minus shaft powerEstimated loss at the chosen operating point
Aggregate motor lossElectrical input minus motor mechanical powerIncludes losses beyond copper heating
Energy validationPmech(f) ≤ V × I(f) over 0 ≤ f ≤ 1Rejects impossible curves; passing does not prove accuracy
Efficiency, power balance and energy checks workflowUse matched motor dataChoose an efficiency inputCheck operating-point lossMeasure the real assembly
Efficiency, power balance and energy checks workflow. Qualification actions; no performance guarantee is implied.

6. Holding and reverse-drive uncertainty

Holding remains unverified for every lead angle in this tool. KHK identifies multiple self-locking factors and recommends another braking mechanism when complete reverse prevention is required. maxon separately explains why reverse behavior must be evaluated on the complete drive.

Reference scope: maxon — Gears: Self-locking or back drivability (updated March 2026).

Holding and reverse-drive uncertainty — decision checklist · Scroll horizontally on small screens.
ConditionWhat remains unknownAction
Power off, steady loadReverse breakaway torqueMeasure both directions within gearhead ratings
Vibration or impactChange in reverse behaviorTest the application disturbance profile
Cold/hot lubricantFriction and breakaway variationRepeat at temperature extremes
Critical suspended or retained loadConsequence of creep or releaseSpecify independently rated retention
Running stall ceilingNot a holding or brake ratingDo not convert it into allowable retained load
Holding and reverse-drive uncertainty workflowDefine the retained loadObtain reverse-load dataTest temperature and shockQualify a separate lock
Holding and reverse-drive uncertainty workflow. Qualification actions; no performance guarantee is implied.

7. Compare architectures before committing

These are engineering comparison questions rather than measured rankings. Compare real candidate drawings and curves at the same shaft load and duty.

Compare architectures before committing — decision checklist · Scroll horizontally on small screens.
ArchitectureReason to investigateTradeoff to verify
Right-angle wormOrthogonal axes may suit shallow packagingSliding losses, reverse behavior and worm support
In-line planetaryCoaxial motor and outputAxial length, load distribution and reverse behavior
Parallel spurAlternative shaft arrangementStage count, envelope and measured noise
Separate brake/lockDocumented holding functionAdded space, actuation power and cost

8. Internal worm thrust versus external shaft loads

For an orthogonal pair, wheel tangential force gives the worm axial reaction magnitude: Fa1 = Ft2 = 2 × T2 / d2, using N·m and meters. At 500 gf·cm and an explicitly assumed 15 mm pitch diameter, this is 6.54 N. The calculator requires your actual pitch diameter; the default is unknown.

Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.

Internal worm thrust versus external shaft loads — decision checklist · Scroll horizontally on small screens.
Load pathWhat the calculator doesWhat it cannot approve
Internal worm axial reactionEstimates 2T/d when pitch diameter is enteredWorm bearings, washers or housing support
External output radial loadCompares entered load and ratingLoad position, bending and combined bearing life
External output axial loadCompares entered load and ratingInternal worm support or combined bearing life
Reversal and shockSteady magnitude onlyImpact, preload, end-float and fatigue
Internal worm thrust versus external shaft loads workflowSeparate internal/external loadsEnter wheel pitch diameterCheck support in both directionsValidate combined loads
Internal worm thrust versus external shaft loads workflow. Qualification actions; no performance guarantee is implied.

9. Materials and manufacturing cost risks

Do not choose a material from nominal ratio alone. Request a documented worm/wheel pair and a drawing-based process plan. The page has no verified hardness, roughness, fatigue life or manufacturing cost data for a custom unit.

Reference scope: ANSI/AGMA 6022-D19 — Design Manual for Cylindrical Wormgearing.

Materials and manufacturing cost risks — decision checklist · Scroll horizontally on small screens.
ChoiceInformation requiredRisk mitigation
Metal worm and bronze wheelAlloy, heat treatment, finish and lubricantReview wear and compatibility together
Polymer wheelResin grade, temperature, creep and lubricant compatibilityTest retained load and thermal cycling
Cut, rolled or ground wormGeometry, volume, tolerances and inspectionQuote the required process and tooling separately
Tighter backlash targetPreload, clearance and thermal toleranceCompare friction and reversal repeatability
Custom support or sealingCAD changes and qualification scopeConfirm NRE, unit cost and sample schedule in writing

10. Lubricant selection and cold-start testing

A lubricant must be selected for the actual gear pair. Klüber identifies ISOFLEX TOPAS NB 52 as a synthetic hydrocarbon/barium-complex bearing grease; that identity alone does not approve it for a particular worm drive. This page prescribes no universal additive, fill percentage or change interval.

Reference scope: Klüber — ISOFLEX TOPAS NB 52 product information.

Lubricant selection and cold-start testing — decision checklist · Scroll horizontally on small screens.
ConditionAsk the supplierCheck on the assembly
Low temperatureApproved viscosity and lubricant gradeStartup current, delay and achieved speed
High temperatureLubricant and seal compatibility limitsHousing and winding temperature
Polymer gears or sealsMaterial compatibility evidenceSwelling, embrittlement and wear
Fill quantityAssembly-specific quantity and locationDrag, distribution and leakage
Maintenance intervalLubrication life evidenceInspect wear and lubricant condition

11. Duty cycle and enclosure qualification

The tool estimates loss at one steady running point. It cannot derive a safe on-time or duty percentage. For repeated run/rest periods, duty fraction = run time / (run time + rest time); equal fractions can produce different peak temperatures when cycle lengths differ.

Duty cycle and enclosure qualification — decision checklist · Scroll horizontally on small screens.
Test variableWhy it mattersRecord before release
Run/rest durationDuty fraction alone hides peak heatingFull torque–speed–time cycle
Motor and gearhead lossesBoth heat the assemblyWinding/housing temperature over the full cycle
Mounting and enclosureChange the heat pathActual bracket, shell and sealing
Supply and protectionStartup and jam behavior differ from steady stateVoltage at motor, current limit and cutoff time
Worst ambientAlters temperature margin and lubricant dragCold start and hot duty tests
Duty cycle and enclosure qualification workflowDefine the actual duty profileMeasure motor and gear lossTest in the final enclosureSet limits from test evidence
Duty cycle and enclosure qualification workflow. Qualification actions; no performance guarantee is implied.

12. Noise, backlash and acceptance criteria

No measured dBA, lost-motion, repeatability or lifetime value is published for these examples. Specify reproducible acceptance conditions before comparing candidate assemblies.

Noise, backlash and acceptance criteria — decision checklist · Scroll horizontally on small screens.
MeasurementControl conditionsDecision criterion
NoiseDistance, background noise, speed, load and mountingApplication-specific limit agreed before samples
BacklashOutput angle at defined reversal torqueMeasured lost motion at the actual load
Position repeatabilityEncoder location and reversal cycleApplication tolerance across temperature
Wear driftCycle profile, lubricant and inspection intervalsChange from initial accepted measurements

13. Three reproducible load scenarios

These are hypothetical arithmetic examples, not customer installations or certified application results. All use the default 6 V, 12,000 RPM, 25 gf·cm stall torque, 50/1,200 mA no-load/stall current, 100:1 ratio and 45% efficiency. Copy each load into the tool to reproduce it.

Computed scenarios — no gearhead ratings or thermal approval supplied · Scroll horizontally on small screens.
Required load (gf·cm)RPMCurrent (mA)Gearbox loss (W)Interpretation and action
50066.67561.110.418Complete both torque ratings and both external load/rating pairs (enter zero only for a known zero load). Missing data remains unverified. Request supplier ratings or send the worksheet for review.
95018.671021.110.223Stall margin is at or below the illustrative 1.5× review threshold, not a standard safety factor. Validate startup, voltage sag and cold lubricant behavior on the actual assembly.
1300012000No running point at or above the modeled stall ceiling. Reduce load or select a different motor/ratio. Any voltage change requires a complete matched motor curve and controller review.
Application fit questions — illustrative review prompts, not compliance claims · Scroll horizontally on small screens.
ApplicationMissing decision dataNext qualification step
Latch actuatorBolt force, linkage arm, jam torque and independent retentionMap force to shaft torque and test jams; no security grade claimed
Metering mechanismLead-screw efficiency, required flow accuracy and device hazardsPerform device-level verification; no medical approval
Outdoor positionerWind torque, exposure, sealing and retained-load requirementTest environmental behavior and retention; no IP or wind rating claimed
Sample release workflowAgree the application criteriaConfirm sample scope and timingTest the actual assemblyReview evidence before release
Sample release workflow. Costs, delivery dates and quality targets require a written agreement.

14. Frequently asked engineering & sourcing questions

[Sizing]What output speed does a 100:1 micro worm gear motor deliver?▼
Divide bare motor speed by the actual ratio, then account for load. The illustrative 6 V curve gives 120 RPM at idealized zero load and 66.67 RPM at 500 gf·cm with 45% assumed efficiency. Neither value is a product rating.
[Sizing]Which torque belongs in the bare motor stall torque input?▼
Use bare motor stall torque before reduction, at the same voltage as all other motor data. The tool applies ratio and assumed efficiency; do not multiply the input by 100.
[Sizing]Why does changing voltage not automatically change speed?▼
Voltage identifies the conditions of the entered curve. Replace no-load speed/current and stall torque/current together with matched data whenever voltage changes.
[Sizing]What happens when the load reaches the stall ceiling?▼
The tool reports no running point: zero speed, zero mechanical output power and modeled stall current. The displayed ceiling is an extrapolation of running efficiency, not delivered or allowable holding torque. Reduce load or select a different assembly.
[Holding]Is a 100:1 micro worm gear motor completely self-locking?▼
The ratio and lead angle cannot prove this. Friction, materials, lubrication, bearings and the complete assembly affect reverse behavior. This tool always leaves holding unverified; obtain supplier reverse-load tests.
[Holding]Can this tool calculate holding torque?▼
No. It has no reverse friction map, brake rating or holding test data. Running torque and the stall ceiling must not be used as a holding rating. Specify an independently rated lock or brake for critical holding.
[Mechanics]Why does the worm shaft need an axial reaction check?▼
Wheel tangential force acts as an axial reaction on the worm. Estimate its magnitude using 2 × wheel torque / wheel pitch diameter. Verify the actual support design in both directions; a specific bearing type is not prescribed here.
[Mechanics]Why is internal thrust shown as unknown?▼
No pitch diameter is supplied in the examples. Enter the actual wheel pitch diameter in millimeters, not its outside diameter. Output shaft external axial ratings do not verify internal worm support.
[Mechanics]Can I enter an exact ratio different from 100:1?▼
Yes, within the stated tool range. For this single worm stage, ratio × worm starts must be a whole wheel tooth count. A compound gearbox needs its own stage geometry review.
[Thermal]Can gearbox loss determine a safe duty cycle?▼
No. The result estimates watts of loss, not winding temperature or allowable run time. Mounting, enclosure, motor loss, ambient temperature and thermal limits must be tested together.
[Lubrication]Which grease should I specify?▼
Request a supplier-approved lubricant for the actual material, speed and temperature. Confirm plastic/seal compatibility, cold-start current and fill quantity. A published lubricant temperature range is not a gearbox rating.
[Acoustics]Does a worm gear guarantee low noise or zero backlash?▼
No. This page publishes no measured noise or backlash rating. Compare assemblies at the same load, speed, microphone distance and mounting; measure reversal lost motion separately.
[Limits]What does within entered limits mean?▼
Both torque ratings and both external load/rating pairs must be present and pass, with no peak-versus-stall warning. Thermal duty, internal support, holding, life and the authenticity of entered data remain unverified.
[Limits]Can this tool approve a motor for medical infusion pump use?▼
No. Device-level flow, occlusion, alarm and safety qualification require independent validation. These illustrative brushed DC calculations provide no medical or application compliance approval.
[Sourcing]Are pricing, stock, and MOQ published on this page?▼
No. Request a quotation for the specified geometry, materials, qualification work and volume. Prototype lead time, tooling costs and production availability need confirmation.
[Sourcing]What should I submit with an RFQ?▼
Send the CSV worksheet, matched motor datasheet, torque–time profile, voltage range, target RPM, shaft drawing, load positions, duty, ambient conditions, holding requirement, volume and required validation evidence.

15. RFQ inputs and qualification evidence

OEM RFQ checklist — missing data is a request for evidence, not a passed check · Scroll horizontally on small screens.
Input categoryWhat to supplyWhat to confirm
ElectricalMatched motor curve, voltage range, supply and current limitStartup, stall protection and controller compatibility
MotionRunning/peak torque, target speed and torque–time profileContinuous and peak ratings with allowable durations
InterfaceShaft/mounting drawings, radial and axial loads plus locationsExact ratio, pitch diameter and internal support capacity
Duty and environmentRun/rest cycle, ambient, enclosure, noise and retention targetsThermal, reverse-load, wear and environmental test evidence
CommercialSamples, annual volume, destination and requested scheduleQuotation, tooling cost, availability and agreed lead time
100:1 worm gear motor sizing tool illustrative worksheet overview
Software execution only; tool-only capture, November 10, 2026. Illustrative inputs: 6 V, 12,000 RPM no-load speed, 50/1,200 mA no-load/stall current, 25 gf·cm bare-motor stall torque, 100:1 ratio, 45% efficiency and 500 gf·cm load; one start, 4.5° lead angle, no pitch diameter or gearhead ratings supplied. Reproduce with Reset Tool. Live results and assumptions above govern the current calculation.

Custom assembly noise, backlash, life, holding torque and allowable duty remain unknown until supplied or tested. No public standard scope or calculator result establishes those values for a specific build.

RFQ Intake

Request a Custom 100:1 Worm Engineering Review

Send the worksheet, matched motor datasheet, duty profile and shaft drawing. Request the missing ratings and an agreed qualification plan.

  • Noise / vibration
  • EMI / current spike
  • Backlash / self-locking
  • Duty cycle / heat rise
  • Life test / traceability
  • Compliance file scope
Email directly

If the form is unavailable, contact [email protected] or WhatsApp WhatsApp Engineering Support. Business RFQ data is used only for engineering review and quotation routing. See the Privacy Policy.

16. Evidence register and model boundaries

Sources checked November 10, 2026. Manufacturer guidance supports general principles; standards listings establish scope and edition only. Full paid standards were not used to certify these equations or any custom assembly. Example inputs, the 1.5× review threshold and application checklists are explicitly illustrative engineering assumptions.

Model boundary: Preliminary fixed-voltage brushed DC linear model with assumed constant right-angle worm gear efficiency. Not a BLDC/controller model. Ignores gearbox idle sliding drag, voltage sag and current limiting; zero-load speed/current are idealized. Efficiency at stall is not defined: the stall ceiling is a screening extrapolation, not available rated continuous torque. Worm self-locking is a static friction property sensitive to vibration, shock, lubrication breakdown, and temperature; it is NOT an approved personal safety brake. Does not calculate internal gear tooth surface contact stress, thermal steady-state temperature rise, lubrication life, or bearing fatigue life. Entered ratings are user data, not independently verified. No continuous-duty, safety-holding or medical approval.